Fire Door Smoke Gaskets
Requires category g system with gasket for fire and possibly smoke.
Fire door smoke gaskets. How to install smoke seals on a fire door. 36x84 48x64 72x84 96x96 etc category b doors additional edge sealing system required see category g. Smoke seals are designed to accomplish this. Category b doors additional edge sealing system required see category g.
In commercial buildings in the united states fire rated doors require special gaskets to prevent smoke from getting through the opening during a fire. This zero 58fs door head and jamb protector prevents sound light air infiltration comes with psa backing to be used as a mortised door gasket and is designed to provide extra fire and smoke protection by utilizing intumescent t echnology. Generally speaking the requirement for intumescent seals or gaskets are a function of the individual manufacturers listing. Not all fire doors and smoke doors are required to have air leakage limited to this level the key is to look for the reference to ul 1784 in the requirements for a specific door location.
Lavalock grey 3 16 x 1 2 bbq smoker cook chamber gasket ll 316 12ss. Category h gasketing smoke and draft control for positive pressure openings. Bbq smoker gaskets and seals for cook chamber lid door firebox on your pit self stick and glue on high temp. This gasket is constructed from high quality durable materials that will outlive many usages.
Hss2000xs88 is furnished in three cut lengths equivalent to standard door dize dimensions i e. For example the ibc requires this limited airflow for fire doors that are also smoke and draft control doors in corridors and smoke barriers. Choose from a wide range of protective products including fire seals caulk backer rods smoke seals astragal base mounts draft seals gap door shoes magnetic seals in addition to other sealing products. For example for a 20 minute fire door on an architect s door schedule the hardware specifier will designate a labeled door and frame positive latching hardware a door closer or automatic closing device and gasketing.
Category g edge sealing systems systems that are surface applied to frames or doors and required for category b doors. Intumescent seals or gaskets are not required on fire rated steel doors. View as grid list. Fire doors even the 20 minute assemblies are subject to completely different criteria than the non fire rated smoke doors.
Intumescent products are typically used for a smoke and fire barrier on wood doors and are activated by heat.