Fire Exit Door Regulations India
Find here fire doors fire exit door manufacturers suppliers exporters in india.
Fire exit door regulations india. Ozone fire safety or fire exit doors are fire rated doors and certified by cbri roorkee for upto 02 hours fire rating. Staircases shall have access through self closing door of one hour fire resistance. Issue 4 2012 detailing the requirements for any fixtures and fittings used with fire doors and fire. It replaces fire certification under the fire precautions act 1971 with a general duty to ensure so far as is reasonably practicable the safety of employees a general duty in relation to non employees to take such fire precautions as may reasonably be required in the circumstances to ensure that premises are safe.
This is accomplished through the use of a closer or spring hinge and a fire rated lockset or exit device. Also the line of sight to an exit sign must be clearly visible at all times. Fire exit doors are the final door on an emergency exit route that must lead to a place of safety. Exit doors must be unlocked at all times.
All fire doors have an additional safety feature they must be self closing and self latching. These are made with high quality material using advanced cnc machines in our iso certified manufacturing facility in himachal pradesh india. 1910 36 d 3 an exit route door may be locked from the inside only in mental penal or correctional facilities and then only if supervisory personnel are continuously on duty and the employer has a plan to. There is an approved document guidance available from the builders hardware industry federation bhif hardware for fire and escape doors.
This order reforms the law relating to fire safety in non domestic premises. Fire safety doors are meant for protecting life in the event of a fire related emergency. These shall be single swing doors opening in the. This is because fire started in the exit door area would effectively cut off the main escape route from the premises.
Doors that connect any room to an exit route. The only thing i would add there is that in the premises that are covered by the rro fire safety and building regulations doors used as the final point of exit should be fire resisting. Keep exit route doors free of decorations or signs that obscure the visibility of exit route doors. National building code of india part iv fire protection as amended from time to time but.
Exit route doors must be free of any device or alarm that could restrict emergency use of the exit route if the device or alarm fails. This means that in the event of a fire all of these doors will close and latch without a person s help. Chapter 7 fire protection and fire safety requirements 7 9 exit requirement as provided in building bye laws 4 8. Post signs along the exit access indicating the direction of travel to the nearest exit and exit discharge if that direction is not immediately apparent.