Fire Exit Door Width Uk
Finally calculate the total exit capacity after discounting the largest exit or exits in the case of ones that are close together as the fire may affect an exit in this case 2 exits for 200 persons each are close together so.
Fire exit door width uk. An exit access must be at least 28 inches 71 1 cm wide at all points. A door that leads directly to a protected stair or a final exit via a protected corridor. Uk standard door sizes 1981 x 457 533 x 35mm door sizes tend to be most popular for use as cupboard or wardrobe doors. A stair is the clear width between the walls or balustrades.
Where there is only one exit access leading to an exit or exit discharge the width of the exit and exit discharge must be at least equal to the width of the exit access. A door in a compartment wall or separating wall leading to an alternative exit. Meet your fire exit door requirements with our custom made range of steel fire exit doors. Fire door sizes how to get it right posted on november 17 2016 just like so many other standards there are several standard door sizes in the uk and as a result ensuring that you select the right one can be something of a challenge.
1981 x 457 533 x 35mm this size is most popular for use as cupboard or wardrobe doors. There is an approved document guidance available from the builders hardware industry federation bhif hardware for fire and escape doors. Specifiers are increasingly influenced to specify only ce marked products for fire and escape doors. Emergency exit specifications and standards.
Hardware consisting of bars that extend to at least half of the width of the door leaf. A staircase that is enclosed throughout its height by a fire resisting structure and doors can sometimes be considered a place of comparative safety. Our steel fire exit doors are made in the uk using modern manufacturing processes guaranteeing a fire escape door that will allow people to leave easily in an emergency. Issue 4 2012 detailing the requirements for any fixtures and fittings used with fire doors and fire.
An escape route is the width at 1 500 mm above floor level when defined by walls or elsewhere the minimum width of passage available between any fixed obstructions. Using the exit width calculations without discounting an exit exit capacity is 700. Above all equip doors with panic hardware and fire exit hardware. Fire exit doors are the final door on an emergency exit route that must lead to a place of safety.
For example this should not be less than 30 inches and not more than 44 inches above the floor.