Fire Rated Door Opening Force
5 0 pounds 22 2 n maximum 2.
Fire rated door opening force. Push until the door opens all the way. 1 1 1 with the exception of fabric fire safety curtain assemblies this standard addresses assemblies that have. To do this first unlatch the door and then press the gauge against the door. Life safety code the international building code ibc and the international fire code ifc.
Door opening force fire doors shall have a minimum opening force allowable by the appropriate administrative authority. Fire rated door assemblies must meet the requirements of the applicable building or life safety code such as the national fire protection association nfpa 80. Spring hinges door spring hinges shall be adjusted so that from the open position of 70 degrees the door shall move to the closed position in 1 5 seconds minimum. A 1 1 see annex k for general information about fire doors.
Fire doors must also be fitted with a fire rated automatic non. Measure door opening force and closing speed. Cbc 1005 1 3 door opening force. The readout on the gauge shows you the force required to open the door.
Sliding or folding door. The force for pushing or pulling open interior swinging egress doors other than fire doors shall not exceed 5 pounds 22 n these forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. The force for pushing or pulling open interior swinging egress doors other than fire doors shall not exceed 5 pounds. The force for pushing or pulling open doors other than fire doors shall be as follows.
The best way to measure door opening force is by using a door force gauge also called a door pressure gauge. This standard regulates the installation and maintenance of assemblies and devices used to protect openings in walls floors and ceilings against the spread of fire and smoke within into or out of buildings. 2 hand activated door opening hardware shall be centered between 30 inches and 44 inches above the floor. 5 0 pounds 22 2 n maximum.
The door shall be set in motion when subjected to a 30 pound force. For other swinging doors as well as sliding and folding doors the door latch shall release when subjected to a i5 pound force. I did a post on opening force for accessibility a while back but it s important to note that fire rated doors are not required to open with 5 pounds of force. Fire doors shall have the minimum opening force allowable by the appropriate administrative authority.
Latching and locking doors that are hand activated and which are in a path of travel shall be operable with a single effort by lever type hardware by panic bars push pull activating bars or other hardware designed to provide passage. Fire door locks must be self latching and are not permitted to have a hold open feature. This is clearly stated in the accessibility standards. I got an email today about a fire rated door that would not reliably close with the closer adjusted to provide 5 pounds of opening force.
Standard for fire doors and other opening protectives nfpa 101.