Fire Rating Of Sheet Metal Ductwork
Further any proposals to incorporate this into bs 9999 should be avoided.
Fire rating of sheet metal ductwork. Firestopping non dampered heating ventilation and air conditioning hvac duct penetrations in fire rated walls is more involved than installing that ubiquitous red caulk into the space between the duct and the periphery of the opening. Lightweight 2 hour fire rated duct. Because of the nature of thin sheet metal ductwork and the physics that come into play during the course of a fire. But when it is used one on each side of a properly framed wall it can become a fire rated wall.
Duct velocity calculate velocities in circular and rectangular ducts imperial and si units online calculator. 25 mm thick pipe covering is used. 2 hour e119 s101 fire rated duct and enclosure. 3 hour fire.
2 hour zero clearance kitchen exhaust duct. Galvanized steel ducts fire rating. Data from both the london fire brigade and the usa give some indication of fires that go beyond room of origin. One sheet of 5 8 type x sheetrock has no fire rating.
Like show 1 like 1. The firestop system is 1 hr and 1 1 2 hr when nom 2 in. 51 mm thick pipe covering is used with 1 hr and 2 hr fire rated walls. Ductwork seal classes ductwork prone to air leakages.
Flameshield we are one of only a few uk companies licensed to manufacture flameshield fire rated ductwork compliant to bs 476 part 24. Ventilation systems for ventilation and air handling air change rates ducts and pressure drops charts and diagrams and more. The hourly t rating of. Specifications methods to determine fire resistance ratings for generic designs can be found in most building codes e g chapter 7 fire resistance rated construction international building code international code council falls church va 2003.
Conditioning ductwork in relation to fire safety and fire protection. I am not aware of a fire rated wall assembly using sheet metal. All the data presented from uk and usa relates to fires which entered the hvac system. Chapter 8 fire resistive materials and construction nfpa 5000 building construction and safety code nfpa quincy ma 2006.
Fire ratings are based on an assembly. This is a non coated certified fire rated ductwork system made from galvanised sheet metal on our dedicated machinery which delivers performance and reliability expected of a leading brand. They are usually 10 x 10 sized ducts. The largest 2 hour fire and blast resistant duct.
Rated floors often use sheet metal pan decking most often with a pour of light weight or standard concrete on top. When 28 gauge steel deck is used the restrained assembly rating 1 1 2 hr. There are some fire tested wall assemblies that are tested with air duct passing through it. Ductwork support ductwork support and recommended.
Question asked by sahawnehmajdi on sep 30 2019 latest reply on oct 5. Sheet metal penetrations are used in rated assemblies and when correctly fire caulked become part of that assembly.